Victron Energy
SmartSolar MPPT Solar Charge Controllers 150/60, 150/70, 150/85, & 150/100
- Regular Price
- $539.75
- Sale Price
- $539.75
- Regular Price
- $635.00
- Unit Price
- translation missing: en.general.accessibility.unit_price_separator
The SmartSolar MPPT solar charge controllers from Victron Energy in the 150 volt series include the following four models 150/60, 150/70, 150/85, and 150/100. The first number in the model name is the maximum PV open circuit voltage and the second number is the rated battery charge current.
Remotely control and monitor the extensive features of your SmartSolar MPPT solar charger with built-in Bluetooth by pairing it with your smartphone or other device via the VictronConnect app. A VE.Direct port enables a wired data connection to a Color Control GX, other GX products, PC or other devices. A remote on-off to connect for example to a VE.BUS BMS. A programmable relay can be programmed to trip on an alarm or other events
Especially in case of a clouded sky, when light intensity is changing continuously, an ultra-fast MPPT controller will improve energy harvest by up to 30% compared to PWM charge controllers and by up to 10% compared to slower MPPT controllers.
If partial shading occurs, two or more maximum power points may be present on the power-voltage curve. Conventional MPPTs tend to lock to a local MPP, which may not be the optimum MPP. The innovative BlueSolar algorithm will always maximize energy harvest by locking to the optimum MPP.
No cooling fan. Maximum efficiency exceeds 98%. The full output current up to 40°C (104°F).
Fully programmable charge algorithm and eight pre-programmed algorithms, selectable with a rotary switch (see manual for details). Includes a LiFePO4 (lithium iron phosphate) battery profile.
Over-temperature protection and power derating when temperature is high. PV short circuit and PV reverse polarity protection. PV reverse current protection.
Compensates absorption and float charge voltage for temperature.
A Smart Battery Sense or a BMV-712 Smart Battery Monitor can be used to communicate battery voltage and temperature to one or more SmartSolar Charge Controllers.
The SmartSolar charge controller will initiate charging even if the battery has been discharged to zero volts. It will also reconnect to a fully discharged Li-ion battery with integrated disconnect function.
Simply remove the rubber seal that protects the plug on the front of the controller and plug-in the SmartSolar Control display.
SmartSolar 150 and 250 Series MPPT Solar Charge Controller User Manual
PWM vs MPPT Solar Charge Controllers
Data Communication of Victron Products
SmartSolar 150 and 250 Series MPPT Solar Charge Controller Datasheet
BlueSolar and SmartSolar MPPT Charge Controllers Overview Guide
GENERAL SPECIFICATIONS |
|
---|---|
Models (Max. PV open circuit voltage/Rated charge current in Amps) |
150/60 150/70 150/85 150/100 |
Rated charge current |
150/60: 60A 150/70: 70A 150/85: 85A 150/100: 100A |
Nominal PV power, 12V See note - 1a,b |
150/60: 860W 150/70: 1000W 150/85: 1200W 150/100: 1450W |
Nominal PV power, 24V See note - 1a,b |
150/60: 1720W 150/70: 2000W 150/85: 2400W 150/100: 2900W |
Nominal PV power, 36V See note - 1a,b |
150/60: 2580W 150/70: 3000W 150/85: 3600W 150/100: 4350W |
Nominal PV power, 48V See note - 1a,b |
150/60: 3440W 150/70: 4000W 150/85: 4900W 150/100: 5800W |
Maximum PV short circuit current See note - 2 |
150/60: 50A 150/70: 50A 150/85: 70A 150/100: 70A |
Maximum PV open circuit voltage |
150V absolute maximum coldest conditions |
Peak efficiency | 98% |
Self-consumption |
Less than 35mA @ 12V / 20mA @ 48V |
Charge voltage 'absorption' | Default setting: 14.4 / 28.8 / 43.2 / 57.6V (adjustable with: rotary switch, display, VE.Direct or Bluetooth) |
Charge voltage 'float' | Default setting: 13.8 / 27.6 / 41.4 / 55.2V (adjustable: rotary switch, display, VE.Direct or Bluetooth) |
Charge voltage 'equalization' | Default setting: 16.2V / 32.4V / 48.6V / 64.8V (adjustable) |
Charge algorithm | multi-stage adaptive (eight pre-programmed algorithms) or user defined algorithm |
Temperature compensation | -16 mV / -32 mV / -64 mV / °C |
Protection | PV reverse polarity / Output short circuit / Over temperature |
Operating temperature | -30 to +60°C (full rated output up to 40°C) |
Humidity | 95%, non-condensing |
Maximum altitude | 5000m (full rated output up to 2000m) |
Environmental condition | Indoor, unconditioned |
Pollution degree | PD3 |
Data communication port | VE.Direct (for details see the data communication white paper) |
Remote on/off | Yes (2 pole connector) |
Programmable relay | DPST AC rating: 240VAC / 4A DC rating: 4A up to 35VDC, 1A up to 60VDC |
Parallel operation | Yes (not synchronized) |
ENCLOSURE |
|
---|---|
Color | Blue RAL 5012 |
PV Terminals |
35 mm² / AWG2 |
Protection category | IP43 (electronic components), IP22 (connection area) |
Weight (kg) |
150/60: 3kg 150/70: 3kg 150/85: 4.5kg 150/100: 4.5kg |
Dimensions (H x W x D) mm |
150/60: 185 x 250 x 95 mm 150/70: 185 x 250 x 95 mm 150/85: 216 x 295 x 103 150/100: 216 x 295 x 103 |
STANDARDS |
|
---|---|
Safety | EN/IEC 62109-1, UL 1741, CSA C22.2 |
Notes |
1a- If more PV power is connected, the controller will limit input power. 1b - The PV voltage must exceed Vbat + 5V for the controller to start. Thereafter the minimum PV voltage is Vbat + 1V. 2 - A PV array with a higher short circuit current may damage the controller. |
How many different bank's battery may I connect to the m?
Thank for your question. The SmartSolar MPPT Solar Charge Controller connects to one bank of batteries (or a single battery). Please refer to the detailed User Manual for the specifics on connections.
If you have any other questions, you can email us at hello@shopweeboats.com.